    X-dock 5300 X-am 8000, DRAEGER 8321882

    Dräger X-am® 8000 Multi-Gas Detector

    Clearance measurement was never this easy and convenient: The 1 to 7 gas detector detects toxic and flammable gases as well as vapors and oxygen all at once – either in pump or diffusion mode. Innovative signaling design and handy assistant functions ensure complete safety throughout the process.

    Specially designed for use with a pump, optimized for clearance measurement. The Dräger X‑am® 8000 is equipped with a very powerful pump. It can be connected with hoses of up to 45 meters in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear, and extends the lifespan of the pump.

    Handy and durable, the Dräger X‑am® 8000 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you.

    The multi-gas detector also features advanced software functions including change of measurement gas for PID, CatEx and IR sensor during operation. This is based on an on-board library and a convenient assistant to hide unused sensor channels and adapt the flexible instrument to the measurement task.

    Standard accessories include a sturdy shoulder strap so you can comfortably carry the X-am 8000. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

    Clearance measurement, release and documentation in no time. The X-am 8000 effectively supports various applications with specially developed assistant functions that guide you through each process step-by-step. During clearance measurement, for example, the smart assistant calculates the necessary flooding time for the device and probe (FKM hose) based on parameters such as measuring gases, temperature limits, and the indicated hose length. Additionally, customer defined flooding times are also possible.

    When monitoring for potentially high methane concentrations, an optional automatic measurement range switch makes it easier to take a reading: If the Cat-Ex sensor measures values above 100 % LEL, the display switches to the range of 0 to 100 vol %. A similar function to measure in % LEL and vol % simultaneously is also available for the IR EX ES sensor.

    The DrägerSensor CatEx 125 PR Gas offers a special variant for the measuring gas methane, which enables measurements in the ppm range.

    Clear signaling design. The signal system of the Dräger X-am 8000 is based on a clear color code:

    • Red light = gas alarm.
    • Yellow light = device-related alarm, e.g. low battery.
    • Green light = device is ready for use.

    The green glow of the D-Light allows you to see from a distance whether the device has been properly tested and is ready for use.

    In case of an alarm, the X-am 8000 alerts you with colorful alarm LEDs, a loud horn (100 dB at a distance of 12 in or 30 cm), and clearly palpable vibration. Optionally, four preset hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows the user to easily recognise the type of hazard based purely on the symbol displayed.

    The X-am 8000 is equipped with an impact detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. These are also documented in the data logger. With this information, a device attendant can specifically check the device. As an option the instrument can be locked after a detected impact as well.

    Economical Fleet Management. Bumptest and calibration are carried out simply and quickly using the Dräger X‑dock® calibrating station. Its low test gas consumption keeps operating costs to a minimum.

    Its reporting function and numerous other useful features make the GDC asset management system a smart addition to any fleet management operation.

    Specialist for high and low hydrocarbon concentrations. To measure hard-to-detect hydrocarbons, you can fit the Dräger X-am 8000 with one of two high-performance PID sensors. The PID HC covers a measurement range of 0 to 2,000 ppm (isobutylene). The PID LC ppb is particularly suited for a measurement range of 0 to 10 ppm (isobutylene) with a high resolution in the range below 1 ppm.

    For benzene-specific measurements, the X-am 8000 can be used with a pre-tube. The advantage: you only need one measuring device for this application, which significantly reduces the costs of purchasing, maintaining and transporting devices in use. The use of the pre-tubes is supported by a built-in assistant.

    Inductive charging protects against wear and tear. The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at once, e.g, when in use inside vehicles or on machinery.

    The charging cradle can connect with one another, taking up minimal space, and are compatible with existing Dräger X-am® series cradles.

    Technical Data

    Key Facts

    • Measurable gases: Ex, CO2, O2, CO, H2S, NO2, SO2, VOC (PID) + (choice of > 40 sensors)
    • Sensorports: 5
    • Number of gases: 1 - 7
    • Sensor technology: CAT + IR + PID + EC

    Applications

    • Personal Air Monitoring: ✓
    • Confined Space Entry: ✓
    • Area Monitoring: ✗

    Technical Data

    • Operation time: >24h Operation time Depends on: Number of alarms, Length of alarms, Temperature, Frequency of turning on the backlight.
    • Degree of protection (IP class): IP 68
    • Dimensions (W × H × D): 3.03x7.05x1.65"
    • Weight: 1.32 lb
    • Battery type: Li-Ion
    • Degree of protection (IP class): IP 68

    Features:

    • Dual sensors: ✓
    • CatEx Fullrange: ✓
    • D-Light: ✓ Glowing green light indicates: tested and ready for use.
    • Internal pump: ✓
    • X-am Pump: ✗ Compatible with the external pump Dräger X-am Pump
    • X-zone 5500 Area Monitoring: ✗ Compatible with the area monitor X-zone 5500 from Dräger
    • Bump Test Station: ✓Compatible with the Bump Test Station from Dräger
    • X-dock Station: ✓Compatible with the calibration and bump test station Dräger X-dock
    • Bluetooth: ✓
    • Bodyguard Alarm (Panic alarm, Motionless detection): ✗
    • Smart Configuraton in Dräger Gas Detection Connect: ✗
    • Support of Dräger ConHub (Gateway): ✗

    Approvals:

    • ATEX: ✓ I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
    • IECEx: ✓ I M1, II 1G, Ex da ia I Ma, Ex da ia IIC T4 Ga
    • c CSA us: ✓ Class I, Zone 0, AEx da ia IIC T4 Ga, Class II, Div 1, Gr. E, F, G
    • CE: ✓
    • GOST (EAC): ✓ PO Ex da ia I Ma X, 0Ex da ia IIC T4 Ga X
    • Performance approval: ✓
    • Shipping approval (MED/DNV GL): ✓

    HAZMAT Item: No

    Minimum Order Quantity: 1

    New: YES

    Quantity per Standard Package: 1

    Type: 8321882, Dräger X-dock 5300 (X-am 8000)

    Unit of Measure: EA