Draeger 8610800, Dräger X‑act® 7000 Analysis System for use with Dräger MicroTubes

Draeger 8610800, Dräger X‑act® 7000 Analysis System for use with Dräger MicroTubes
    Catalog # Draeger-8610800
    Our Price

    $4,700.00

    List Price $5,875.00

    Description

    Dräger X‑act® 7000 Multi-Gas Detector, Draeger 8610800

    The innovative Dräger X‑act® 7000 analysis system consists of Dräger MicroTubes and an opto-electronic analysis device that lets you precisely measure gases in the low ppb range. It gives you precise results right on site, replacing slow, expensive lab analyses. It's extremely easy to use: insert the Dräger MicroTubes, start measuring, then read out the test result.

    Benefits:

    Measures the lowest-quantity concentrations with lab-quality analysis. Concentrations of hazardous substances in ambient workplace air must never exceed the defined limits. Monitoring these sometimes very low concentration levels is a responsible task. The Dräger X-act 7000 in combination with Dräger MicroTubes is focused on measuring carcinogenic and toxic substances in the low ppb range. This sensitive testing system is based on colorimetric chemical sensors capable of replacing conventional laboratory analysis and providing precise results right on site. This saves time and money.

    More safety thanks to high selectivity. The substance-specific reactive layers and multiple pre-layers in the Dräger MicroTubes allow for selective gas testing. The various layers serve as a filter. During testing, they filter out other substances that occur in the workplace so that only the target substance is reflected in the test result. This significantly reduces cross-sensitivities and the number of false-positive test results.

    Explosion-proof and ready to use. The RFID tags applied to the Dräger MicroTubes contain all the calibration data that apply throughout their normal lifespan of one year. This eliminates the need for lengthy function tests and manual calibration. Because it works on the basis of mass-flow measurement, air pressure fluctuations have no influence on the device. Any possible temperature or humidity influences are already accounted for during the factory calibration. The analyzer is explosion-proof and certified under ATEX and CSA. The system is also dust- and splash-resistant in accordance with IP54. It also meets the requirements for electromagnetic compatibility under EN 61326-1.

    Easy to use. After an automatic self-test, the X-act 7000 analysis system is immediately ready for use. It is suitable for testing with all available Dräger MicroTubes. Simply insert the right Dräger MicroTube for your testing needs. The automatic drive carefully draws the MicroTube in and positions it. Control your test using the 3-button control and 2.4 inch colour display. When the test is complete, the green LED will glow and a message is displayed on the screen. You can store the test result, location and time in the internal data logger and read it later using the Dräger CC Vision software. The device is powered by five easily replaceable AA alkaline batteries. The battery life lasts for more than ten hours of testing and can be read on the display.

    Also suitable for remote sampling. Using the coupler (connector piece), the Dräger X‑am® Pump can be attached to the X-act 7000. This allows you to test for carcinogenic and toxic substances in the ppb range, even in hard-to-reach places like ducts, pipelines or tanks up to a distance of 45 meters (147 feet). Because the X-am Pump is also certified explosion-proof for Zone 0, it is perfectly suited for these tasks.

    System Components:

    Dräger MicroTubes: With each set of MicroTubes, you can perform 10 tests. The concentrations of hazardous substances are shown on the X-act® 7000 display. Specific MicroTubes even allow you to perform tests in the ppb range. The RFID tag applied to the Dräger MicroTube set contains all the calibration data that apply throughout their normal lifespan of one year. This eliminates the need for lengthy function tests and manual calibration.

    Accessories:

    Dräger X‑am® Pump for Dräger X‑act® 7000. The Dräger X‑am® Pump is an external pump for portable gas detection devices. In combination with the X-act® 7000, it allows you to perform remote testing (for example, inside tanks or ducts). To use it, simply attach the pump to the Dräger X‑act® 7000 using a coupler. Control the pump using the X-act® 7000 software.

    Coupler. The coupler is the connector between the Dräger X‑act® 7000 analysis system and the Dräger X‑am® Pump. It creates a secure, sealed connection between the two devices.

    PVC hose With PTFE inner-hose. Available in two lengths: 3 m (9.8 ft) and 15 m (49.2 m).

    Probes. 50 cm (20 in)– Rigid, 70 cm (27 in)– Flexible semi-rigid, 90 cm (35 in)– Rigid, 150 cm (59 in)– Telescopic.

    Pre-tube holder. Pre-tube holders are needed to improve the sensitivity and selectivity of some Dräger MicroTubes even further. The pre-tube holder ensures a secure, sealed connection with the Dräger X‑act® 7000.

    HAZMAT Item: No

    Minimum Order Quantity: 1

    New: YES

    Quantity per Standard Package: 1

    Type: 8610800, X-act 7000

    Unit of Measure: EA