GfG 2210-031, Dynagard 25 Series for O2, Stand-alone Systems, Stand Alone Instruments, Dynagard 25 Series system with ZD 21 transmitter for detecting oxygen (O2) and GMA 41B single channel controller (no power supply) , 0 - 25% vol., 0.1% vol.

GfG 2210-031, Dynagard 25 Series for O2, Stand-alone Systems, Stand Alone Instruments, Dynagard 25 S
    Catalog # GfG-2210-031
    Our Price

    $2,295.00

    List Price $2,868.75

    Description

    Dynagard 25 Series for O2, Stand-alone Systems, Stand Alone Instruments, Dynagard 25 Series system with ZD 21 transmitter for detecting oxygen (O2) and GMA 41B single channel controller (no power supply) , 0 - 25% vol., 0.1% vol., GfG 2210-031

    Dynagard 25 Series O2 - Single point fixed oxygen monitoring system.

    Simple and effective

    The Dynagard 25 Series accurately measures oxygen levels. The unit offers a local display, a horn / strobe, and a linear 4-20 mA output. The Dynagard 25 Series offers a safe and reliable gas warning system.

    Alarm points

    Each alarm can be adjusted separately. The alarm point values can be freely adjusted within the detection range of the transmitter. Every alarm point value can be set to over range / under range, latching / non-latching, or resettable / non-resettable.

    Alarm relays

    The controller provides four voltage-free relays for the three alarms and one fault warning. The relays may be used to control additional alarm devices like lights or horns. They can even prompt specific counter measures to prevent or limit dangers from gases or vapors.

    ZD21 zirconia sensor

    The comprehensive electronics allow for easy operation and maintenance and also increase operational safety and accuracy. In less than 2 seconds, the ZD21 responds to an oxygen deficiency. The sensor has a platinum coating on the inside and outside of the ceramic cylinder. Oxygen is electrochemically reduced at the cathode. The voltage produced is proportional to the net difference in the partial pressures of oxygen in the reference gas versus the sampled gas. This extremely short response time allows the user the time to take measures to prevent considerable damage.

    Technical Data: Dynagard 25 Series O2 - Single point fixed oxygen monitoring system.

    Gas: Oxygen O2.
    Detection range: 0-25% volume.
    Measuring principle: Zirconia oxide (ZD).
    Gas supply: Diffusion.
    Expected sensor life: Greater than 5 years.
    Temperature: +32 to +122 °F / 0 to +55 °C.
    Humidity: 0 to 99% r.h. non-condensing.
    Pressure: 920 to 1,100 hPA.
    Output signal: Linear 4-20 mA.
    Power supply: 24 V DC wall pack.
    Display: 3-digit LED display for linear measurement values, service.
    • 1 LED green – operational status.
    • 1 LED yellow – fault.
    • 3 LEDs red – alarm.
    • Display of max / min values.
    Horn: Low - 70 dB at 10 ft per UL 464 / High - 83 dB at 10 ft per UL 464.
    Strobe: Light output on axis (cd).
    • Low - 35.
    • High - 68.
    Alarms:  3 alarm points, user adjustable within the detection range.
    Alarm functions available:.
    • Latching / non-latching.
    • Resettable / non-resettable.
    • Hysteresis adjustable.
    • Delay-time 0 to 2 minutes.
    • Alarm thresholds adjustable.
    Relays:.
    • 3 alarm points, 1 fault – voltage free.
    • Factory settings.
    • A1 - strobe.
    • A2 - open.
    • A3 - horn.
    • Fault - open.
    • Voltage: 250 V AC 50/60 Hz or 250 V DC maximum.
    Dimensions:  11 x 7 x 2.75 in / 27.9 x 17.8 x 7 cm (H x W x D).
    Weight:  6.5 lbs / 2.95 kg.

    HAZMAT Item: No

    New: Yes

    Type: 2210-031, Dynagard 25 Series for O2, Stand-alone Systems, 0 - 25% vol. 0.1% vol. ,

    Product Docs & Literature

    close
    Dynagard-25-Series-Stand-Alone-O2-Instrument-GfG GfG-Engineered-Fixed-Gas-Detection-Systems-Index