    ZD21 Series, Fixed Transmitter, Transmitter, Base unit (no sensor), GfG 2210009E

    ZD21 Series Fixed Transmitters - Long-term monitoring of oxygen concentrations in difficult conditions, by GfG Instrumentation

    ZD21 Transmitter - Monitor O2 in difficult conditions. In many areas of application, oxygen concentrations must be monitored consistently. If harsh environmental conditions such as varying temperatures, high or low pressure or dry or humid air necessitate a particularly durable transmitter, the ZD21 is a good choice. The sensor operates with a zirconium dioxide oxygen pump cell. This measuring principle enables stable long-term measurement of O2 in difficult conditions and with short response times.

    The ZD21 is characterized by its high selectivity and long-term stability. They can be equipped with oxygen sensors for different measuring ranges. These range from very low concentrations (0 to 1000 pm) to high concentrations (0 to 96 vol %).The sensor can also be installed remotely, with a maximum cable length of two meters between the transmitter and the external sensor.

    Sturdy and durable

    The transmitter housing is made of aluminum. It is protected against the ingress of dust and water (IP54). The O2 sensors have a sensor lifetime of approximately five years and are not susceptible to CO2. Temperatures between -30 and +50 °C, very low or very high humidity and extreme pressure do not affect the accuracy of the oxygen measurement.

    Communication and service

    Changes in the O2 concentration are detected within a very short time (t90 > 2 s). The ZD21 uses an analog (0.2-1 mA or 4-20 mA) signal to communicate with the controller. Test gases for function tests can be inserted via an optional calibration adapter. On-site adjustment can be performed by a single technician.

    Key features and General Information at a glance:

    • Measuring principle: Zirconium dioxide (ZD).
    • For oxygen.
    • Optional remote sensor (maximum cable length: 2 m).
    • Short response time (t90 < 2 s).
    • Expected sensor lifetime: 5 years.
    • Signal transmission: 0.2-1 mA or 4-20 mA.
    • Protection class: IP54.

    Optionally available:

    Flow adapter, remote calibration adapter, weatherproof housing.