GfG 2801-60-001, CC28, Fixed Transmitter, Transmitter with sensor - standard catalytic sensor 0-50% LEL (MK 219-1), Hydrogen H2 - No Display

GfG 2801-60-001, CC28, Fixed Transmitter, Transmitter with sensor - standard catalytic sensor 0-50%
    Catalog # GfG-2801-60-001
    Our Price

    $1,445.00

    List Price $1,806.25

    Description

    CC28, Fixed Transmitter, Transmitter with sensor - standard catalytic sensor 0-50% LEL (MK 219-1), Hydrogen H2 - No Display, GfG 2801-60-001

    CC28 Fixed Transmitter, Detecting combustible gases in Ex zone 1, by GfG Instrumentation

    CC28 Transmitter - For flammable gases and vapors in Ex zones.

    Various models for different applications. Choose from the: CC28 without Display & Alarm/ CC28 D with Display & without Alarm/ CC28 DA with Display and Alarm.

    If combustible gases and vapors are to be monitored in Ex zones, the CC28 transmitter is a reliable and economical solution. The CC28 uses an analog (4-20 mA) signal to provide measured values and status information. The special stack effect ensures very short response times of only a few seconds for fast warning of explosion hazards. In combination with GfG's reliable controllers, it can be installed in new gas detection systems or retrofitted into existing ones.

    The CC28 uses catalytic combustion (CC) to detect combustible gases and vapours such as methane, propane and hydrogen. The long-life sensors make the CC28 an economical solution for detecting a wide range of combustible gases in the measurement ranges of 0 to 100% LEL and 0 to 4% by volume (NH3). Its automatic temperature compensation and the linearization of the measurement signals ensure high measurement accuracy.

    Explosion protection, functional safety and device protection

    The CC28 has ATEX certification for use in Ex Zone 1, and its hardware complies with the European Functional Safety Standard DIN EN 61508-2: 2011 (SIL). The housing is protected against ingress of dust and water (protection class: IP64). An optional weatherproof housing provides additional protection.

    Communication and service

    Signals are transmitted via the analog industry standard (4-20 mA). The CC28 uses two status LEDs to indicate its operating status. Service and adjustments are carried out on site using the optional RC2 remote control (one-man adjustment). The pre-adjusted sensors can be easily replaced thanks to Smart Sensor technology. Test gases for function tests can be inserted using a flow adapter.

    Key features and General information at a glance:

    • Measuring principle: catalytic combustion (CC).
    • For flammable gases and vapors.
    • Short response time due to stack effect.
    • Expected sensor lifetime: 5 years.
    • Signal transmission: 4-20 mA.
    • Protection class: IP64.

    Approvals / Certifications:

    • ATEX certification: II 2G Ex demb [ib] IIC T4 Gb.

    • SIL 2/3 (hardware).

    Optionally available:

    • operating unit RC2, windshield, weatherproof housing, flow-through adapter.

    Detectable Gases

    LEL combustible gases, C2H2 Acetylene, C2H4 Ethylene, C2H6O Ethanol, C2H6 Ethane, C2H6O Dimethyl ether, C3H4 Propine, C3H6 Propene, C3H6O Acetone, C3H6O22 Methyl acetate, C3H8 Propane, C3H8O n-Propanol, C4H8O 2-Butanon (MEK), C4H8O2 Ethyl acetate, C4H10 n-Butane, C4H10O n-Butanol, C5H12 Pentane (n), C6H6 Benzene, C6H12 Cyclohexane, C6H12O Methyl isobutyl ketone (MIBK), C6H14 n-Hexane, C7H8 Toluene, C7H16 n-Heptane, C8H18 Octane (n), C9H20 n-Nonane, CH4 Methane, CH4O Methanol, CO Carbon monoxide, H2 Hydrogen, NH3 Ammonia.