GfG 2811-712-001, EC28, Fixed Transmitter, Transmitters with sensor, Chlorine dioxide (ClO2) - No Display , 0 - 1 ppm

GfG 2811-712-001, EC28, Fixed Transmitter, Transmitters with sensor, Chlorine dioxide (ClO2) - No Di
    Catalog # GfG-2811-712-001
    Our Price

    $1,890.00

    List Price $2,362.50

    Product Documents

    Data Sheet

    Description

    EC28, Fixed Transmitter, Transmitters with sensor, Chlorine dioxide (ClO2) - No Display , 0 - 1 ppm, GfG 2811-712-001

    EC28 Series Fixed Transmitters: EC28, EC28 D, EC28 DA, EC28 DAR, EC28 B, EC28 DB, EC28 DAB, by GfG Instrumentation

    EC28 Gas Detection Transmitter - The smart transmitter.

    Advanced technology

    Wherever hazards are expected, the EC28 transmitter and GfG’s proven monitoring systems are the right choice for reliable surveillance. The ATEX-certified design, an integrated, explosion proof buzzer, and bright alarm LEDs provide the highest safety in hazardous areas by including visual and audible alarms. The gas alarm not only alerts the person in the control room of hazards, but also the person on-site.

    Easy handling

    Smart sensor technology allows a user to install the transmitter or to replace a sensor within a few seconds – just plug the sensor into the transmitter. Adjustments are done directly at the transmitter using touch keys or with the remote control (one-person calibration).

    RC2 Remote Control (optional)

    Ammonia and hydrogen are lighter than air. With the transmitter installed close to the ceiling, GfG can provide permanently connected cables with plugs for the remote control, which allow the user to do all adjustments without having to climb a ladder. In addition, one remote control can be used for several transmitters, which helps cut costs and increase efficiency.

    The remote control display is always identical to that of the transmitter, making inspection, service, and calibration considerably simple. The remote control reads the current gas concentration and can be used as an external display.

    The EC28 series offers several solutions

    The EC28 is the “blind” version for Ex zone protection without a display but economical where you have several transmitters and a single RC 2 remote control to view the readings of each one.

    The EC28 D model shows the current gas concentration on-site at the display of the transmitter and also at GfG’s GMA controller.

    The EC28 DA provides additional bright alarm LEDs and a buzzer – avoiding costs for a separate Explosion proof horn and an explosion proof light. You also save money on wiring to connect the controller and alarm devices.

    The EC28 B is similar to the EC28 in that it is a “blind” version without display but this model has Modbus communication.

    The EC28 DB model has display and communication is carried out using RS-485 industry standard with Modbus protocol.

    The EC28 DAB includes display, alarm and Modbus and is also suitable for use in Ex zone areas.

    In combination with GfG’s flexible control units, the EC28 provides various possibilities for reliable and cost-effective gas monitoring.

    For intrinsically safe needs, please reference the EC28 i / Di product brochure.

    Reliable measurement and minimal cost of operation

    Accurate sensors and integrated temperature compensation provide the highest measurement accuracy. Low maintenance requirements and the long sensor life reduce your cost of ownership.

    Display and control operations

    The EC28 D (with display) transmitter features a 2.2 inch LC display and three control buttons. In normal operation, the display shows the measured value or information on faults or alarms. In addition, the operating parameters (sample gas, measuring range, limit values, etc.) can be retrieved using the operating keys.

    EC28 Transmitter Feature summary

    • Concentration display at transmitter or at remote control.
    • Ex-proof visual and audible alarms.
    • No need for expensive Ex-proof buzzer or wiring.
    • Easy sensor replacement by means of plug-in smart sensors.
    • Long sensor life.
    • Permanent status and function display at transmitter.
    • Adjustments without opening the casing using touch keys or remote control; easy handling even for hard-to-reach transmitters positions (e.g. at the ceiling)

    Detectable gases:

    • AsH3 Arsine.
    • B2H6 Diborane.
    • Br2 Bromine gas.
    • C2H4O Ethylene oxide.
    • Cl2 Chlorine.
    • ClO2 Chlorine dioxide.
    • CO Carbon monoxide.
    • COCl2 Phosgene.
    • H2 Hydrogen.
    • H2S Hydrogen sulfide.
    • HCl Hydrogen chloride.
    • HCN Hydrogen cyanide.
    • HF Hydrogen fluoride.
    • NH3 Ammonia.
    • NO Nitrogen monoxide.
    • NO2 Nitrogen dioxide.
    • O2 Oxygen.
    • O3 Ozone.
    • PH3 Phosphine.
    • SiH4Silane.
    • SO2 Sulfur dioxide.
    • Other gases on request.