Catalog # | GfG-2901-99-004 |
Our Price |
$3,230.00 |
List Price | $4,037.50 |
IR29 i Series Fixed Intrinsically safe Transmitter for flammable gases, by GfG Instrumentation
IR29 i Transmitters - Safe monitoring of LEL. If flammable gases and vapors need to be monitored in Ex zone 0, the intrinsically safe IR29 i transmitter is a reliable and robust solution. The IR29 i transmits measured values and status displays in analog (4-20 mA). It is connected via a safety barrier (SB1, SB1 D or Zener barrier) to prevent the ignition of power lines within the Ex zone. In combination with GfG's proven controllers, installation in new gas detection systems as well as retrofitting in existing systems is possible.
The IR29 i uses non-dispersive infrared (NDIR) sensor technology to detect combustible gases and vapors. Our patented 4-beam and 4-wavelength technology with gold-plated mirror optics, which do not require any beam splitters, is used to ensure selective measurement results without false alarms. The infrared sensors used also enable measurements above the lower explosion limit (LEL), do not require oxygen and are not susceptible to sensor poisons. The long-life sensors make the IR29 i a permanently reliable solution for detecting a wide range of combustible gases and vapors in the 0 to 100 % LEL measuring range. Its automatic temperature compensation and the linearization of the measurement signals ensure high measurement accuracy.
Communication and service
The IR29 i communicates via the 4-20 mA industry standard signal. Two status LEDs are used to indicate its operation status. If you use one of our safety barriers with display, measured values and status indications can also be read safely outside the Ex zone. Service and adjustments are performed on site using the optional RC2 remote control (one-person adjustment). The IR29 I's self-monitoring function increases device safety between maintenance intervals. Test gases for function tests and adjustments can be inserted via a calibration adapter.
Safety and instrument protection
The IR29 i is ATEX-certified for use in Ex zone 0. It complies with the intrinsic safety "i" standard, which is required for use in many industrial and mining applications. The V4A stainless steel and poly-carbonate housing is protected against ingress of dust and water (protection class: IP67). Available accessories include a guard plate and dust filter.
Key features and General Information at a glance:
• Measuring principle: Infrared (IR).
• Measuring principle: infrared (IR).
• For combustible gases and vapors.
• Intrinsically safe.
• Not susceptible to sensor poisons.
• Expected sensor lifetime: 6 years.
• Signal transmission: 4-20 mA.
• Protection class: IP67.
• Integrated data logger.
Approvals / Certifications:
ATEX certification: II 1G Ex ia IIC T4 Ga.
Optionally available:
Safety barrier, pressure and humidity sensors, ex-proof control unit RC2, impact protection, flow adapter, calibration adapter, protection plate, dust filter, weatherproof housing, flow adapter.
Detectable gases:
LEL combustible gases.
• C2H2 Acetylene.
• C2H4 Ethylene.
• C2H6O Ethanol.
• C3H8 Propane.
• C3H8O n-Propanol.
• C4H10 n-Butane.
• CH4 Methane.
• CO2 Carbon dioxide.
• Other gases on request.
HAZMAT Item: No
New: Yes
Type: 2901-99-004, IR29 i (Intrinsically Safe) Fixed Transmitter, 0 - 100% LEL