Google Leads Image
Home     Account     Cart
Find "Products By Category" below left and center, or enter Part Number or Keywords in "Enter Keywords" box above right.

GfG 744, GfG Respiratory airline monitor with standard (0-99 ppm) CO sensor (to be used with approved filter panel), 744 , Instrument Only

GfG 744, GfG Respiratory airline monitor with standard (0-99 ppm) CO sensor (to be used with approve
    Catalog # GfG-744
    Our Price

    $1,150.00

    List Price $1,437.50

    Description

    GfG Respiratory airline monitor with standard (0-99 ppm) CO sensor (to be used with approved filter panel), 744, Instrument Only, GfG 744

    RAM 744 Autocal® CO Monitor

    • To be used with Portable or Wall mounted or Portable RAM 744 Filter Panels for continuous in-line CO monitoring.
    • Low maintenance, dependable, long-life Electrochemical sensor.
    • Three stage filtration for up to 8 users when used with RAM 744 Filter Panels.

    RAM Filter Panels Available separately in:

    • 25 CFM (maximum of 2 ports).
    • 50 CFM (maximum of 4 ports).
    • 100 CFM (maximum of 8 ports).

    The RAM 744 is the ideal monitor for portable applications and where space is limited. It is mounted with the filtration system, allowing for rapid response and eliminating the possibility of sample lines becoming blocked or crimped. The flow rate is fixed so there are no touchy flow meters to adjust.

    Calibration and maintenance are made simple with our innovative AutoCal® system that allows the CO sensor to be calibrated with a test gas connection and the flip of a switch. The alarm level is set to 10 ppm. The compact, portable "air case" encloses the three-stage 25, 50 or 100 CFM filter panel with the RAM 744 CO monitor in a rugged carrying case*. All models have quick-connect inlets and outlets.

    Any GfG Instrumentation RAM instrument can be custom-configured to meet the needs of the end user's exact specifications.

    Respiratory air specifications

    All GfG Instrumentation RAM instruments satisfy the requirements of OSHA rule 29 CFR 1910.134 (d) (2) (ii) for carbon monoxide monitoring. They will also monitor Grade E air, generally specified for breathing air in cylinders (SCBA).

    OSHA Regulations (Standard - 29 CFR)
    Respiratory Protection - 1910.134

    (i) (6)
    For compressors that are not oil-lubricated, the employer shall ensure that carbon monoxide levels in the breathing air do not exceed 10 ppm.

    (i) (7)
    For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm.

    HAZMAT Item: No

    Type: GfG 744, GfG Respiratory airline monitor with standard (0-99 ppm) CO sensor (to be used with approve

    close
    GfG-RAM-744-Monitor GFG-Portable-Gas-Detection-All-Products West-Chester-By-Product-Number