GfG 9100-744-H, GfG 100 CFM portable filter panel with low H2 interference CO-H sensor, maximum of 8 ports, 744 , Instruments with Complete Filter Panel

GfG 9100-744-H, GfG 100 CFM portable filter panel with low H2 interference CO-H sensor, maximum of 8
    Catalog # GfG-9100-744-H
    Our Price

    $4,735.00

    List Price $5,918.75

    Description

    GfG 100 CFM portable filter panel with low H2 interference CO-H sensor, maximum of 8 ports, 744, Monitor with Complete Filter Panel, GfG 9100-744-H

    RAM 744 Autocal® CO Monitor and Portable Filtration Panel

    The RAM 744 is the ideal monitor for portable applications and where space is limited. It is mounted with the filtration system, allowing for rapid response and eliminating the possibility of sample lines becoming blocked or crimped. The flow rate is fixed so there are no touchy flow meters to adjust.

    Calibration and maintenance are made simple with our innovative AutoCal® system that allows the CO sensor to be calibrated with a test gas connection and the flip of a switch. The alarm level is set to 10 ppm. The compact, portable - air case - encloses the three-stage 25, 50 or 100 CFM filter panel with the RAM 744 CO monitor in a rugged carrying case*. All models have quick-connect inlets and outlets.

    Any GfG Instrumentation RAM instrument can be custom-configured to meet the needs of the end user's exact specifications.

    Respiratory air specifications

    All GfG Instrumentation RAM instruments satisfy the requirements of OSHA rule 29 CFR 1910.134 (d) (2) (ii) for carbon monoxide monitoring. They will also monitor Grade E air, generally specified for breathing air in cylinders (SCBA).

    OSHA Regulations (Standard - 29 CFR)
    Respiratory Protection - 1910.134

    (i) (6)
    For compressors that are not oil-lubricated, the employer shall ensure that carbon monoxide levels in the breathing air do not exceed 10 ppm.

    (i) (7)
    For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm.

    HAZMAT Item: No

    Type: GfG 9100-744-H, GfG 100 CFM portable filter panel with low H2 interference CO-H sensor, maximum of 8