Catalog # | MSA-H3015-8004 |
Our Price |
$618.80 |
List Price | $892.50 |
Product Family:
MSA Bacharach's H-10 PRO Ultra-sensitive Universal Refrigerant Leak Detector
MSA Bacharach’s H-10 PRO is a highly responsive universal refrigerant leak detector using
Bacharach’s tried-and-true heated diode sensor technology. It’s ultra-sensitive to all halogen-based, non-flammable CFC, HFC and HCFC refrigerants for reliable use in a wide range of refrigerant leak detection applications.
The H-10 PRO has a long probe (4.5 ft./1.4 m) for detecting leaks in hard-to-reach areas, visual and audible indicators to show relative leak sizes and an auto-zeroing feature (automatic mode only) for finding leaks in backgrounds where target gas is present. It has an internal sensor calibration reference to ensure optimum performance and comes with a 3 year warranty.Specifications:
APPROVALS: CE mark.
AUTOMATIC BACKGROUND ADJUSTMENT: Yes, in automatic mode.
DIMENSIONS: Unit: 8.3 × 10.5 × 5.4 in. (21.1 × 26.7 × 13.7 cm), Probe: 4.5 ft. (1.37 m).
FLOW RATE: 90 cc/min @ small setting (typical).
LEAK INDICATORS: Visual (red LED in probe tip) and audible (via internal speaker or headphones).
OPERATING CONDITIONS: 32 to 104 °F (0 to 40 °C), 10 to 90% RH (non-condensing), 1 ATM.
POWER: 12 VDC internal rechargeable battery or via 100-240 VAC wall adapter/charger.
RECHARGING TIME: 3-4 hours with wall adapter (included).
REFRIGERANTS DETECTED1 All CFC, HFC and HCFC refrigerants, including but not limited to: R-12, R-22, R-134a, R-404A, R-410A, R-502, R-507, HFO-1233zd, HFO-1234yf and HFO-1234ze.
RESPONSE TIME: 1 second.
RUN TIME: 3 hours (typical) on fully-charged battery.
SENSITIVITY2: 0.006 oz/yr (stationary), 0.1 oz/yr (moving per SAE J2791).
SENSOR LIFE3: 1 year (typical).
SENSOR TYPE: Heated diode.
WARM-UP TIME: 2 minutes (approximate).
WEIGHT: 5.1 lbs. (2.3 kg).
WARRANTY: 3 years (does not include sensor, filters, refrerence leak bottle, battery or probe).
1 DO NOT use this device to detect for leaks of refrigerants which are rated as combustible/flammable gases (e.g., ASHRAE A2- or A3-rated refrigerants).
2 Sensitivity for R-12, R-22, R-124a, R-410A, R-404A and R-507 when unit is set to small leak setting, manual mode.
3 Based on normal use. Consistent and/or constant exposure to high levels of refrigerant will deteriorate the sensor life more quickly. Increasing the sensor heater will also impact sensor life.
Country of Origin: USA
HAZMAT Item: NO
New: YES
Type: H3015-8004, H-10 PRO BACH N.AM. PLUG